Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -8,7 +8,7 @@ 8 8 9 9 General parameters of BMS Main X are configured in the «Control → General» section: 10 10 11 -[[image:1740747822632-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 83" width="600"]]11 +[[image:1740747822632-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="800"]] 12 12 13 13 In this section: 14 14 ... ... @@ -20,11 +20,11 @@ 20 20 21 21 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 22 22 23 -[[image:1740747928147-952.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 170" width="600"]]23 +[[image:1740747928147-952.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]] 24 24 25 25 The network addresses of the battery modules are configured in the "Control - Modules - Node IDs" section: 26 26 27 -[[image:1740747965546-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 189" width="600"]]27 +[[image:1740747965546-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="252" width="800"]] 28 28 29 29 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main or BMS Mini S / BMS Mini 2 settings. 30 30 ... ... @@ -36,7 +36,7 @@ 36 36 37 37 Calculation of the battery state of charge (SOC) is configured in the "Control - Calculation - Final SOC" section: 38 38 39 -[[image:1740749535746-215.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 80" width="600"]]39 +[[image:1740749535746-215.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="106" width="800"]] 40 40 41 41 The following battery SOC calculation methods are supported: 42 42 ... ... @@ -52,7 +52,7 @@ 52 52 53 53 === Main contactor === 54 54 55 -The BMS Main 3X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.55 +The BMS Main X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 56 56 57 57 The Main contactor algorithm supports the following modes: 58 58 ... ... @@ -73,6 +73,36 @@ 73 73 74 74 To change the parameters of the main contactor, select the "Control → Main contactor" section: 75 75 76 +[[image:1740749605680-464.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="800"]] 77 + 78 +In this section: 79 + 80 +* Enable – a flag to enable the main contactor control; 81 +* Algorithm – main contactor control algorithm: 82 +** Always on – contactor is always closed; 83 +** Automatic – contactor closes by internal charge and discharge algorithms; 84 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed, millisecond; 85 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, millisecond; 86 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset; 87 +* Errors to open the main contactor – error flags that cause the contactor to open. 88 + 89 +=== Charging status === 90 + 91 +To change the parameters for generating status signals when charging the battery, select the section “Control → Charging status”: 92 + 93 +[[image:1740749824773-539.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="104" width="800"]] 94 + 95 +In this section: 96 + 97 +* Current corresponding to charging – a current level to set the "Charging current present" signal, A; 98 +* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A. 99 + 100 +=== Discharging status === 101 + 102 +To change the parameters for generating status signals when discharging the battery, select the section “Control → Discharging status”: 103 + 104 +[[image:1740749862820-455.png]] 105 + 76 76 === Charge === 77 77 78 78 The BMS Main X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit.
- 1740749824773-539.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.4 KB - Content
- 1740749862820-455.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.2 KB - Content