Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -170,7 +170,7 @@ 170 170 171 171 The battery charge management is configured in the "Control - Charge" section: 172 172 173 -[[image:174 0750130950-113.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="800"]]173 +[[image:1749657043032-397.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="253" width="800"]] 174 174 175 175 In this section: 176 176 ... ... @@ -183,12 +183,15 @@ 183 183 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 184 184 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 185 185 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 186 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 186 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 187 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 187 187 * Control the precharging contactor – a flag to control the main precharging contactor; 188 188 * Canceling charging time – a delay before opening the main charging contactor, ms; 189 189 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 190 190 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 191 191 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 193 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 194 +* Regulator: Gain – a gain of current regulator; 192 192 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 193 193 * Errors to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 194 194 * Errors to open the charging contactor – errors that cause the main charging contactor "Charging" to open; ... ... @@ -228,8 +228,9 @@ 228 228 229 229 The battery discharge management is configured in the "Control - Discharge" section: 230 230 231 -[[image:1740750247231-926.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="800"]] 232 232 235 +[[image:1749657087238-544.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="250" width="800"]] 236 + 233 233 In this section: 234 234 235 235 * Enable – a flag to enable battery discharge controller; ... ... @@ -241,12 +241,15 @@ 241 241 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 242 242 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 243 243 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 244 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 248 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 249 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 245 245 * Control the precharging contactor – a flag to control the main precharging contactor; 246 246 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond; 247 247 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 248 248 * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 249 249 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 255 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 256 +* Regulator: Gain – a gain of current regulator; 250 250 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 251 251 * Errors to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 252 252 * Errors to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open, ... ... @@ -294,7 +294,7 @@ 294 294 295 295 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 296 296 297 -[[image:174 0750424118-190.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="250" width="800"]]304 +[[image:1749657114587-360.png]] 298 298 299 299 In this section: 300 300