... ... @@ -129,6 +129,7 @@ 129 129 “Precharge error” generation conditions if any of the following is true: 130 130 131 131 * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts"; 132 +* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts"; 132 132 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 133 133 134 134 (% class="box warningmessage" %)