... ... @@ -129,7 +129,6 @@
129 129  “Precharge error” generation conditions if any of the following is true:
130 130  
131 131  * the precharge current does not decrease during the "Precharge time" after "Number of precharging attempts";
132 -* voltages before and after contactors are not equal during the "Precharge time" after "Number of precharging attempts";
133 133  * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time.
134 134  
135 135  (% class="box warningmessage" %)
... ... @@ -171,7 +171,7 @@
171 171  
172 172  The battery charge management is configured in the "Control - Charge" section:
173 173  
174 -[[image:1740750130950-113.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="219" width="800"]]
173 +[[image:1749657043032-397.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="253" width="800"]]
175 175  
176 176  In this section:
177 177  
... ... @@ -184,12 +184,15 @@
184 184  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
185 185  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
186 186  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
187 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
186 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
187 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
188 188  * Control the precharging contactor – a flag to control the main precharging contactor;
189 189  * Canceling charging time – a delay before opening the main charging contactor, ms;
190 190  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
191 191  * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared;
192 192  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
193 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
194 +* Regulator: Gain – a gain of current regulator;
193 193  * Maximum charge current limit – a maximum allowed charging current of all battery, A;
194 194  * Errors to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
195 195  * Errors to open the charging contactor – errors that cause the main charging contactor "Charging" to open;
... ... @@ -229,8 +229,9 @@
229 229  
230 230  The battery discharge management is configured in the "Control - Discharge" section:
231 231  
232 -[[image:1740750247231-926.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="218" width="800"]]
233 233  
235 +[[image:1749657087238-544.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="250" width="800"]]
236 +
234 234  In this section:
235 235  
236 236  * Enable – a flag to enable battery discharge controller;
... ... @@ -242,12 +242,15 @@
242 242  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
243 243  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
244 244  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
245 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
248 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
249 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
246 246  * Control the precharging contactor – a flag to control the main precharging contactor;
247 247  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
248 248  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
249 249  * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared;
250 250  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
255 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
256 +* Regulator: Gain – a gain of current regulator;
251 251  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
252 252  * Errors to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
253 253  * Errors to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open,
... ... @@ -295,7 +295,7 @@
295 295  
296 296  The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section:
297 297  
298 -[[image:1740750424118-190.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="250" width="800"]]
304 +[[image:1749657114587-360.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="284" width="800"]]
299 299  
300 300  In this section:
301 301  
... ... @@ -311,7 +311,8 @@
311 311  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
312 312  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
313 313  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
314 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
320 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
321 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
315 315  * Control the precharging contactor – a flag to control the main precharging contactor;
316 316  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
317 317  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared;
... ... @@ -318,6 +318,8 @@
318 318  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared;
319 319  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
320 320  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
328 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
329 +* Regulator: Gain – a gain of current regulator;
321 321  * Maximum charge current limit – a maximum allowed charging current of all the battery, A;
322 322  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
323 323  * Errors to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
1749656740041-432.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +52.8 KB
Content
1749656910340-570.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +52.0 KB
Content
1749657005161-877.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +58.3 KB
Content
1749657043032-397.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +52.8 KB
Content
1749657087238-544.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +52.0 KB
Content
1749657114587-360.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +58.3 KB
Content