Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -62,12 +62,12 @@ 62 62 In “Always on” mode main contactor closes if all the following is true: 63 63 64 64 * Other contactors are open; 65 -* There are no errors from the "Errors ..." bitfiled. 65 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 66 66 67 67 In “Always on” mode main contactor opens if all the following is true: 68 68 69 69 * Other contactors are open; 70 -* There is an error from the the "Errors ..." bitfiled. 70 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 71 71 72 72 In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 73 73 ... ... @@ -161,7 +161,7 @@ 161 161 162 162 The operation of **closing the main charging contactor** is described in the following steps: 163 163 164 -1. The main charging contactor is open. When the “Charge request” is received, the re are noerrorsfromthe"Errors..."bitfield, and the battery modules are joined, go to step 2.164 +1. The main charging contactor is open. When the “Charge request” is received, the voltage and current unbalance errors (“Voltage unbalance (CH)”, “Current unbalance (CH)”, “Charging current unbalance”) are cleared, and the battery modules are joined, go to step 2. 165 165 1. Closing the main precharging contactor (optional). Go to step 3. 166 166 1. Closing the main charging contactor ("Charging" signal). Go to step 4. 167 167 1. The main charging contactor is closed. If the "Charge request" is cleared, the battery modules are disconnected, or the "Critical error" occurs, go to step 1. ... ... @@ -220,7 +220,7 @@ 220 220 221 221 The operation of **closing the main discharging contactor **is described in the following steps: 222 222 223 -1. The main discharging contactor is open. When the “Discharge request” is received, the re are noerrorsfromthe"Errors..."bitfield, and the battery modules are joined, go to step 2.223 +1. The main discharging contactor is open. When the “Discharge request” is received, the voltage and current unbalance errors (“Voltage unbalance (DCH)”, “Current unbalance (DCH)”, “Discharging current unbalance”) are cleared, and the battery modules are joined, go to step 2. 224 224 1. Closing the main precharging contactor (optional). Go to step 3. 225 225 1. Closing the main discharging contactor ("Discharging" signal). Go to step 4. 226 226 1. The main discharging contactor is closed. If the "Discharge request" is cleared, the battery modules are disconnected, or the "Critical error" occurs, go to step 1. ... ... @@ -413,7 +413,7 @@ 413 413 * Discharge: Tolerant cell temperature difference, °C; 414 414 * Delay before starting the coolant pump, millisecond; 415 415 * Delay before stopping the coolant pump, millisecond; 416 -* Errors to turn off the coolant pump – errors that cause the coolant pump to shut down. 416 +* Errors 1 (2) to turn off the coolant pump – errors that cause the coolant pump to shut down. 417 417 418 418 Conditions for signal generation: 419 419