Changes for page 3.3 Control

Last modified by Admin on 2025/06/11 15:52

From version 2.1
edited by Admin
on 2025/02/28 13:03
Change comment: Загрузить новое вложение 1740747822632-731.png
To version 5.1
edited by Admin
on 2025/02/28 13:32
Change comment: Загрузить новое вложение 1740749535746-215.png

Summary

Details

Page properties
Content
... ... @@ -4,16 +4,30 @@
4 4  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Control ==
6 6  
7 +=== General parameters ===
8 +
9 +General parameters of BMS Main X are configured in the «Control → General» section:
10 +
11 +[[image:1740747822632-731.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="600"]]
12 +
13 +In this section:
14 +
15 +* Initialization delay – a delay before processing functions after finishing device initialization (initialization includes current sensors calibration and battery modules search), millisecond.
16 +
7 7  === Battery modules ===
8 8  
9 -The BMS Main X allows up to 8 battery modules to be connected in parallel.
19 +The BMS Main X allows up to 32 battery modules to be connected in parallel.
10 10  
11 -Flags for enabling battery modules are configured in the "Control - Modules - Enable" section:
21 +Flags for enabling battery modules are configured in the "Control Modules Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section:
12 12  
13 -[[image:1734356553568-438.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="156" width="600"]]The network addresses of the battery modules are configured in the "Control - Modules - Node IDs" section:
23 +[[image:1740747928147-952.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="170" width="600"]]
14 14  
15 -[[image:1734356553571-342.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="175" width="600"]]Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity CAN” section of the BMS Main or BMS Mini S / BMS Mini 2 settings.
25 +The network addresses of the battery modules are configured in the "Control - Modules - Node IDs" section:
16 16  
27 +[[image:1740747965546-449.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="189" width="600"]]
28 +
29 +Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main or BMS Mini S / BMS Mini 2 settings.
30 +
17 17  === Calculation of battery parameters ===
18 18  
19 19  The BMS Main X device calculates battery parameters based on user settings.
1740747928147-952.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +28.8 KB
Content
1740747965546-449.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +34.0 KB
Content
1740749535746-215.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +15.5 KB
Content