Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -149,7 +149,6 @@ 149 149 150 150 The device controls two processes: **joining battery modules **and **closing the main charging contactor.** 151 151 152 - 153 153 The operation of the **joining battery modules** is described by the following steps: 154 154 155 155 1. Battery modules are disabled. When the “Join to charge” request is received and the voltage and current unbalance errors (Voltage unbalance (CH), Current unbalance (CH), Charging current unbalance) are cleared, go to step 2. ... ... @@ -161,7 +161,7 @@ 161 161 162 162 The operation of **closing the main charging contactor** is described in the following steps: 163 163 164 -1. The main charging contactor is open. When the “Charge request” is received, the voltage and currentunbalanceerrors(“Voltageunbalance (CH)”, “Currentunbalance(CH)”, “Charging currentunbalance”) are cleared, and the battery modules are joined, go to step 2.163 +1. The main charging contactor is open. When the “Charge request” is received, there are no errors from the "Errors ..." bitfield, and the battery modules are joined, go to step 2. 165 165 1. Closing the main precharging contactor (optional). Go to step 3. 166 166 1. Closing the main charging contactor ("Charging" signal). Go to step 4. 167 167 1. The main charging contactor is closed. If the "Charge request" is cleared, the battery modules are disconnected, or the "Critical error" occurs, go to step 1. ... ... @@ -208,7 +208,6 @@ 208 208 209 209 The device controls two processes: **joining battery modules** and **closing the main discharging contactor**. 210 210 211 - 212 212 The operation of the** joining battery modules** is described by the following steps: 213 213 214 214 1. Battery modules are disabled. When the “Join to discharge” request is received and the voltage and current unbalance errors (Voltage unbalance (DCH), Current unbalance (DCH), Discharging current unbalance) are cleared, go to step 2. ... ... @@ -220,7 +220,7 @@ 220 220 221 221 The operation of **closing the main discharging contactor **is described in the following steps: 222 222 223 -1. The main discharging contactor is open. When the “Discharge request” is received, the voltage and currentunbalanceerrors(“Voltageunbalance (DCH)”, “Currentunbalance(DCH)”, “Discharging current unbalance”) are cleared, and the battery modules are joined, go to step 2.221 +1. The main discharging contactor is open. When the “Discharge request” is received, there are no errors from the "Errors ..." bitfield, and the battery modules are joined, go to step 2. 224 224 1. Closing the main precharging contactor (optional). Go to step 3. 225 225 1. Closing the main discharging contactor ("Discharging" signal). Go to step 4. 226 226 1. The main discharging contactor is closed. If the "Discharge request" is cleared, the battery modules are disconnected, or the "Critical error" occurs, go to step 1.