... ... @@ -62,12 +62,12 @@ 62 62 In “Always on” mode main contactor closes if all the following is true: 63 63 64 64 * Other contactors are open; 65 -* There are no errors from the "Errors 1, 2..." bitfileds.65 +* There are no errors from the "Errors ..." bitfiled. 66 66 67 67 In “Always on” mode main contactor opens if all the following is true: 68 68 69 69 * Other contactors are open; 70 -* There is an error from the the "Errors 1, 2..." bitfileds.70 +* There is an error from the the "Errors ..." bitfiled. 71 71 72 72 In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 73 73 ... ... @@ -413,7 +413,7 @@ 413 413 * Discharge: Tolerant cell temperature difference, °C; 414 414 * Delay before starting the coolant pump, millisecond; 415 415 * Delay before stopping the coolant pump, millisecond; 416 -* Errors 1 (2)to turn off the coolant pump – errors that cause the coolant pump to shut down.416 +* Errors to turn off the coolant pump – errors that cause the coolant pump to shut down. 417 417 418 418 Conditions for signal generation: 419 419