Changes for page 3.3 Control
Last modified by Admin on 2025/06/11 15:52
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -398,29 +398,5 @@ 398 398 399 399 * the maximum temperature among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 400 400 401 -=== Coolant pump === 402 402 403 -To change the parameters of the coolant pump control algorithm, select the "Control → Coolant pump" section: 404 - 405 -[[image:1740750960467-987.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]] 406 - 407 -In this section: 408 - 409 -* Enable – a flag to enable the coolant pump control; 410 -* Charge: Maximum cell temperature difference, °C; 411 -* Charge: Tolerant cell temperature difference, °C; 412 -* Discharge: Maximum cell temperature difference, °C; 413 -* Discharge: Tolerant cell temperature difference, °C; 414 -* Delay before starting the coolant pump, millisecond; 415 -* Delay before stopping the coolant pump, millisecond; 416 -* Errors 1 (2) to turn off the coolant pump – errors that cause the coolant pump to shut down. 417 - 418 -Conditions for signal generation: 419 - 420 -* the maximum temperature difference among all cells of the battery is greater than the “Charge (Discharge): Maximum cell temperature difference” value during the “Delay before starting the coolant pump” time. 421 - 422 -Conditions for clearing the signal: 423 - 424 -* the maximum temperature difference among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature difference” value during the “Delay before stopping the coolant pump” time. 425 - 426 426
- 1740750960467-987.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.8 KB - Content