... ... @@ -62,12 +62,12 @@ 62 62 In “Always on” mode main contactor closes if all the following is true: 63 63 64 64 * Other contactors are open; 65 -* There are no errors from the "Errors 1, 2..." bitfileds.65 +* There are no errors from the "Errors ..." bitfiled. 66 66 67 67 In “Always on” mode main contactor opens if all the following is true: 68 68 69 69 * Other contactors are open; 70 -* There is an error from the the "Errors 1, 2..." bitfileds.70 +* There is an error from the the "Errors ..." bitfiled. 71 71 72 72 In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 73 73 ... ... @@ -373,4 +373,54 @@ 373 373 374 374 * the minimum temperature among all cells of the battery is greater than the “Charge (Discharge): Tolerant cell temperature” value during the “Delay before stopping the heater” time. 375 375 376 +=== Cooler === 377 + 378 +To change the parameters of the cooler control algorithm, select the "Control → Cooler" section: 379 + 380 +[[image:1740750844486-213.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]] 381 + 382 +In this section: 383 + 384 +* Enable – a flag to enable the cooler control; 385 +* Charge: Maximum module temperature, °C; 386 +* Charge: Tolerant module temperature, °C; 387 +* Discharge: Maximum module temperature, °C; 388 +* Discharge: Tolerant module temperature, °C; 389 +* Delay before starting the cooler, millisecond; 390 +* Delay before stopping the cooler, millisecond; 391 +* Errors 1 (2) to turn off the cooler – errors that cause the cooler to shut down. 392 + 393 +Conditions for signal generation: 394 + 395 +* the maximum temperature among all cells of the battery is greater than the “Charge (Discharge): Maximum cell temperature” value during the “Delay before starting the cooler” time. 396 + 397 +Conditions for clearing the signal: 398 + 399 +* the maximum temperature among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature” value during the “Delay before stopping the cooler” time. 400 + 401 +=== Coolant pump === 402 + 403 +To change the parameters of the coolant pump control algorithm, select the "Control → Coolant pump" section: 404 + 405 +[[image:1740750960467-987.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]] 406 + 407 +In this section: 408 + 409 +* Enable – a flag to enable the coolant pump control; 410 +* Charge: Maximum cell temperature difference, °C; 411 +* Charge: Tolerant cell temperature difference, °C; 412 +* Discharge: Maximum cell temperature difference, °C; 413 +* Discharge: Tolerant cell temperature difference, °C; 414 +* Delay before starting the coolant pump, millisecond; 415 +* Delay before stopping the coolant pump, millisecond; 416 +* Errors to turn off the coolant pump – errors that cause the coolant pump to shut down. 417 + 418 +Conditions for signal generation: 419 + 420 +* the maximum temperature difference among all cells of the battery is greater than the “Charge (Discharge): Maximum cell temperature difference” value during the “Delay before starting the coolant pump” time. 421 + 422 +Conditions for clearing the signal: 423 + 424 +* the maximum temperature difference among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature difference” value during the “Delay before stopping the coolant pump” time. 425 + 376 376
- 1740750960467-987.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.8 KB - Content