... ... @@ -373,4 +373,54 @@
373 373  
374 374  * the minimum temperature among all cells of the battery is greater than the “Charge (Discharge): Tolerant cell temperature” value during the “Delay before stopping the heater” time.
375 375  
376 +=== Cooler ===
377 +
378 +To change the parameters of the cooler control algorithm, select the "Control → Cooler" section:
379 +
380 +[[image:1740750844486-213.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="158" width="800"]]
381 +
382 +In this section:
383 +
384 +* Enable – a flag to enable the cooler control;
385 +* Charge: Maximum module temperature, °C;
386 +* Charge: Tolerant module temperature, °C;
387 +* Discharge: Maximum module temperature, °C;
388 +* Discharge: Tolerant module temperature, °C;
389 +* Delay before starting the cooler, millisecond;
390 +* Delay before stopping the cooler, millisecond;
391 +* Errors 1 (2) to turn off the cooler – errors that cause the cooler to shut down.
392 +
393 +Conditions for signal generation:
394 +
395 +* the maximum temperature among all cells of the battery is greater than the “Charge (Discharge): Maximum cell temperature” value during the “Delay before starting the cooler” time.
396 +
397 +Conditions for clearing the signal:
398 +
399 +* the maximum temperature among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature” value during the “Delay before stopping the cooler” time.
400 +
401 +=== Coolant pump ===
402 +
403 +To change the parameters of the coolant pump control algorithm, select the "Control → Coolant pump" section:
404 +
405 +[[image:1740750960467-987.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="154" width="800"]]
406 +
407 +In this section:
408 +
409 +* Enable – a flag to enable the coolant pump control;
410 +* Charge: Maximum cell temperature difference, °C;
411 +* Charge: Tolerant cell temperature difference, °C;
412 +* Discharge: Maximum cell temperature difference, °C;
413 +* Discharge: Tolerant cell temperature difference, °C;
414 +* Delay before starting the coolant pump, millisecond;
415 +* Delay before stopping the coolant pump, millisecond;
416 +* Errors 1 (2) to turn off the coolant pump – errors that cause the coolant pump to shut down.
417 +
418 +Conditions for signal generation:
419 +
420 +* the maximum temperature difference among all cells of the battery is greater than the “Charge (Discharge): Maximum cell temperature difference” value during the “Delay before starting the coolant pump” time.
421 +
422 +Conditions for clearing the signal:
423 +
424 +* the maximum temperature difference among all cells of the battery is less than the “Charge (Discharge): Tolerant cell temperature difference” value during the “Delay before stopping the coolant pump” time.
425 +
376 376  