Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/04/09 12:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,6 +18,16 @@ 18 18 19 19 [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]] 20 20 21 +=== Temperature sensors === 22 + 23 +Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 24 + 25 +[[image:1740747277464-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]] 26 + 27 +In this section: 28 + 29 +* Type – a type of temperature sensors. 30 + 21 21 === Discrete outputs === 22 22 23 23 The BMS Main X device has **4 digital outputs**. For each discrete output, its assignment and inversion flag are set. ... ... @@ -26,10 +26,8 @@ 26 26 27 27 [[image:1734356322699-904.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]] 28 28 29 - The devicesupports thefollowing digital outputassignments:39 +A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 30 30 31 -* No output – output is not used. 32 - 33 33 Inversion flags for discrete outputs are configured in the "Signals - Output discrete signals - Inversion" section: 34 34 35 35 [[image:1734356322700-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="600"]] ... ... @@ -43,14 +43,8 @@ 43 43 44 44 [[image:1734356322702-918.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="600"]] 45 45 46 - Thedevice supportsthe following relayassignments:54 +A list of available relay assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 47 47 48 -* No relay – relay is not used; 49 -* Charging – main charging contactor; 50 -* Precharging – main precharging contactor; 51 -* Discharging – main discharging contactor; 52 -* Charging/Discharging – main charging/discharging contactor. 53 - 54 54 Inversion flags for relays are configured in the “Signals – Relays – Inversion” section: 55 55 56 56 [[image:1734356322702-133.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="100" width="600"]]
- 1740747277464-849.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +18.5 KB - Content