Wiki source code of 3.2 Inputs and outputs

Last modified by Admin on 2025/04/09 12:33

Show last authors
1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Configuration =
3
4 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 == Inputs and outputs ==
6
7 === Discrete inputs ===
8
9 The BMS Main X device has **4 discrete inputs** of the "dry contact" type. For each discrete input, its assignment and inversion flag are set.
10
11 Assignments of discrete inputs are configured in the "Signals - Input discrete signals - Assignments" section:
12
13 [[image:1734356322695-445.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="600"]]
14
15 (% class="box infomessage" %)
16 (((
17 A list of available discrete input assignments is available in [[Input signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
18 )))
19
20 Inversion flags for discrete inputs are configured in the "Signals - Input discrete signals - Inversion" section:
21
22 [[image:1734356322698-182.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="113" width="600"]]
23
24 === Temperature sensors ===
25
26 Temperature sensors settings are configured in the "Signals → Temperature sensors" section:
27
28 [[image:1740747277464-849.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="67" width="600"]]
29
30 In this section:
31
32 * Type – a type of temperature sensors.
33
34 === Discrete outputs ===
35
36 The BMS Main X device has **4 digital outputs (+5V)**. For each discrete output, its assignment and inversion flag are set.
37
38 Assignments of discrete outputs are configured in the "Signals - Output discrete signals - Assignments" section:
39
40 [[image:1734356322699-904.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]]
41
42 (% class="box infomessage" %)
43 (((
44 A list of available discrete output assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
45 )))
46
47 Inversion flags for discrete outputs are configured in the "Signals - Output discrete signals - Inversion" section:
48
49 [[image:1734356322700-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="111" width="600"]]
50
51
52 === Relays ===
53
54 The BMS Main X device has **3 opto-relays** for controlling main contactors. For each opto-relay, its assignment and inversion flag are set.
55
56 Assignments of relays are configured in the "Signals - Relays - Assignments" section:
57
58 [[image:1734356322702-918.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="600"]]
59
60 (% class="box infomessage" %)
61 (((
62 A list of available relay assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.2\. Strings controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
63 )))
64
65 Inversion flags for relays are configured in the “Signals – Relays – Inversion” section:
66