Changes for page 3.1 General information

Last modified by Admin on 2025/03/27 15:21

From version 2.3
edited by Admin
on 2025/02/28 12:42
Change comment: There is no comment for this version
To version 3.1
edited by Admin
on 2025/02/28 12:43
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -18,13 +18,21 @@
18 18  
19 19  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
20 20  
21 -* TCP connection: set up the device IP address.
21 +* **TCP connection:** set up the device IP address.
22 22  
23 23  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234420521-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
24 24  
25 25  
26 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
26 +When connected, the device asks for an access password.
27 27  
28 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
29 +
30 +|=User|=Default Password|=Description
31 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
32 +|User|user|A common user access with permissions to change almost all the settings
33 +|Service|service|A service account for battery manufacturers. Has access to some additional settings
34 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
35 +
28 28  [[image:1734356185622-553.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]]
29 29  
30 30  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":