1 -Настройка осуществляется с помощью программы ElectricDeviceMonitor версии не ниже 1.17.3 (доступна по [[ссылке>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) по
1 +Configuring can be done using the ElectricDeviceMonitor above the 1.17.3 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via
2 2  
3 3  * USB;
4 -* CAN bus (поддерживаются адаптеры Systec, PEAK, Marathon и USB-CAN);
5 -* TCP connection (для этого должны быть установлены BMS Wi-Fi или BMS LANmodule).
4 +* CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
5 +* TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main X).
6 6  
7 -After connecting, the device is identified as a device with a serial interface (COM port) as in the figure below:
7 +To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window.
8 8  
9 -[[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1733743515976-982.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="300" width="450"]]
10 -
11 -To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window, specify the name of the device's COM port, and click the "Launch monitor" button:
12 -
13 13  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
14 14  
15 15   Choose the connection type and set up connection settings:
16 16  
17 -* Serial port (USB): choose the corresponding COM port;
13 +* **Serial port (USB)**: choose the corresponding COM port;
18 18  
19 19  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]][[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
20 20  
21 -* Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN: select the device in device list, specify the CAN speed and BMS device address:
17 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN:** select the device in device list, specify the CAN speed and BMS device address:
22 22  
23 23  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
24 24  
25 -* TCP connection: set up the device IP address.
21 +* **TCP connection:** set up the device IP address.
26 26  
27 27  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234420521-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
28 28  
29 29  
30 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
26 +When connected, the device asks for an access password.
31 31  
28 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
29 +
30 +|=User|=Default Password|=Description
31 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
32 +|User|user|A common user access with permissions to change almost all the settings
33 +|Service|- (by request)|A service account for battery manufacturers. Has access to some additional settings
34 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
35 +
32 32  [[image:1734356185622-553.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]]
33 33  
34 34  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":