... ... @@ -1,5 +3,3 @@
1 -This document describes settings and states of the BMS Main X device.
2 -
3 3  Configuring can be done using the ElectricDeviceMonitor above the 1.17.3 (available by the [[link>>url:http://movicomelectric.com/wa-data/public/site/app/ElectricDeviceMonitorSETUP.exe]]) via
4 4  
5 5  * USB;
... ... @@ -6,10 +6,6 @@
6 6  * CAN bus (Systec, PEAK, Marathon and USB-CAN adapters are supported);
7 7  * TCP connection (BMS Wi-Fi or BMS LANmodule must be installed on BMS Main X).
8 8  
9 -After connecting, the device is identified as a device with a serial interface (COM port) as in the figure below:
10 -
11 -[[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1733743515976-982.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="300" width="450"]]
12 -
13 13  To connect to the device, launch ElectricDeviceMonitor, select "Unified monitor" in the main program window, specify the name of the device's COM port, and click the "Launch monitor" button:
14 14  
15 15  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1735233230234-960.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="340" width="450"]]
... ... @@ -16,21 +16,29 @@
16 16  
17 17   Choose the connection type and set up connection settings:
18 18  
19 -* Serial port (USB): choose the corresponding COM port;
13 +* **Serial port (USB)**: choose the corresponding COM port;
20 20  
21 21  [[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484262-545.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="311" width="450"]][[image:Battery management systems.BMS Main 3.3\. Configuration.3\.1 General information.WebHome@1733320484267-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
22 22  
23 -* Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN: select the device in device list, specify the CAN speed and BMS device address:
17 +* **Systec USB-CAN, PEAK USB-CAN, Marathon USB-CAN, BMS USB-CAN:** select the device in device list, specify the CAN speed and BMS device address:
24 24  
25 25  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234432178-528.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
26 26  
27 -* TCP connection: set up the device IP address.
21 +* **TCP connection:** set up the device IP address.
28 28  
29 29  [[image:Battery management systems.BMS Mini S.3\. Configuration.3\.1 General information.WebHome@1735234420521-941.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="248" width="450"]]
30 30  
31 31  
32 -When connected, the device asks for an access password. For the "User" account, the default password is "user" (without quotes).
26 +When connected, the device asks for an access password.
33 33  
28 +Below is the list of available users. Default passwords can be changed in "Device -> Change password" menu.
29 +
30 +|=User|=Default Password|=Description
31 +|Guest|guest|Guest access to view battery state. No permissions to change and view any settings
32 +|User|user|A common user access with permissions to change almost all the settings
33 +|Service|service|A service account for battery manufacturers. Has access to some additional settings
34 +|Manufacturer|-|This account is used by BMS manufacturer and not accessible for others
35 +
34 34  [[image:1734356185622-553.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="468" width="600"]]
35 35  
36 36  After successful authentication, the device will send settings and state profiles, which will be displayed as two tabs: "Settings" and "State":