Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main X.WebHome1 +drafts.BMS Main X.WebHome - Content
-
... ... @@ -20,7 +20,6 @@ 20 20 )))|105 × 115 × 15 21 21 |Mounting dimensions (length × width), mm|99 × 109 22 22 |Mounting holes|M3 23 -|Headers X1, X3-X8 type|Molex series Micro-Fit 24 24 25 25 == Connection == 26 26 ... ... @@ -66,9 +66,11 @@ 66 66 67 67 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 68 68 68 +1. 69 + 69 69 === Х5 – header for CAN (EXT) interface === 70 70 71 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 72 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]][[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 72 72 73 73 |**Pin**|**Name**|**Description** 74 74 |**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system) ... ... @@ -76,56 +76,4 @@ 76 76 |**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA 77 77 |**4**|**CAN_EXT_GND**|Isolated ground 78 78 79 -=== J2 – jumper for switching CAN (EXT) terminal resistor === 80 - 81 -To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure: 82 - 83 -[[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 84 - 85 -=== Х6 – header for sold-state relays === 86 - 87 -[[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]] 88 - 89 -|**Pin**|**Name**|**Description** 90 -|**1**|**NO1**|Normally open contact of the relay 1 91 -|**2**|**NO2**|Normally open contact of the relay 2 92 -|**3**|**NO3**|Normally open contact of the relay 3 93 -|**4**|**COM1**|Common contact of the relay 1 (55V, 2A) 94 -|**5**|**COM2**|Common contact of the relay 2 (55V, 2A) 95 -|**6**|**COM3**|Common contact of the relay 3 (55V, 2A) 96 - 97 -=== X7 – header for discrete inputs/outputs === 98 - 99 -[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]] 100 - 101 -|**Pin**|**Name**|**Description** 102 -|**1**|**GND**|Discrete input 1 “dry contact” (ground) 103 -|**2**|**GND**|Discrete input 2 “dry contact” (ground) 104 -|**3**|**GND**|Discrete input 3 “dry contact” (ground) 105 -|**4**|**GND**|Discrete input 4 “dry contact” (ground) 106 -|**5**|**-**|- 107 -|**6**|**GND**|Discrete output 1 (ground) 108 -|**7**|**GND**|Discrete output 2 (ground) 109 -|**8**|**GND**|Discrete output 3 (ground) 110 -|**9**|**GND**|Discrete output 4 (ground) 111 -|**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V) 112 -|**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V) 113 -|**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V) 114 -|**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V) 115 -|**14**|**-**|- 116 -|**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA) 117 -|**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA) 118 -|**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA) 119 -|**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA) 120 - 121 -=== Х8 – header for temperature sensors === 122 - 123 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 124 - 125 -|**Pin**|**Name**|**Description** 126 -|**1**|**TEMPG1**|Ground of the thermistor 1 127 -|**2**|**TEMPG2**|Ground of the thermistor 2 128 -|**3**|**TEMP1**|Signal from the thermistor 1 129 -|**4**|**TEMP2**|Signal from the thermistor 2 130 - 131 131
- 1734355584041-898.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -12.0 KB - Content
- 1734355584043-416.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -24.8 KB - Content