Last modified by Admin on 2025/03/18 12:50

From version 6.1
edited by Admin
on 2025/02/06 11:39
Change comment: There is no comment for this version
To version 2.1
edited by Admin
on 2024/12/16 13:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -Battery management systems.BMS Main X.WebHome
1 +drafts.BMS Main X.WebHome
Content
... ... @@ -20,7 +20,6 @@
20 20  )))|105 × 115 × 15
21 21  |Mounting dimensions (length × width), mm|99 × 109
22 22  |Mounting holes|M3
23 -|Headers X1, X3-X8 type|Molex series Micro-Fit
24 24  
25 25  == Connection ==
26 26  
... ... @@ -66,9 +66,11 @@
66 66  
67 67  [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]]
68 68  
68 +1.
69 +
69 69  === Х5 – header for CAN (EXT) interface ===
70 70  
71 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
72 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]][[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
72 72  
73 73  |**Pin**|**Name**|**Description**
74 74  |**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system)
... ... @@ -76,56 +76,4 @@
76 76  |**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA
77 77  |**4**|**CAN_EXT_GND**|Isolated ground
78 78  
79 -=== J2 – jumper for switching CAN (EXT) terminal resistor ===
80 -
81 -To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure:
82 -
83 -[[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]]
84 -
85 -=== Х6 – header for sold-state relays ===
86 -
87 -[[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]]
88 -
89 -|**Pin**|**Name**|**Description**
90 -|**1**|**NO1**|Normally open contact of the relay 1
91 -|**2**|**NO2**|Normally open contact of the relay 2
92 -|**3**|**NO3**|Normally open contact of the relay 3
93 -|**4**|**COM1**|Common contact of the relay 1 (55V, 2A)
94 -|**5**|**COM2**|Common contact of the relay 2 (55V, 2A)
95 -|**6**|**COM3**|Common contact of the relay 3 (55V, 2A)
96 -
97 -=== X7 – header for discrete inputs/outputs ===
98 -
99 -[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]]
100 -
101 -|**Pin**|**Name**|**Description**
102 -|**1**|**GND**|Discrete input 1 “dry contact” (ground)
103 -|**2**|**GND**|Discrete input 2 “dry contact” (ground)
104 -|**3**|**GND**|Discrete input 3 “dry contact” (ground)
105 -|**4**|**GND**|Discrete input 4 “dry contact” (ground)
106 -|**5**|**-**|-
107 -|**6**|**GND**|Discrete output 1 (ground)
108 -|**7**|**GND**|Discrete output 2 (ground)
109 -|**8**|**GND**|Discrete output 3 (ground)
110 -|**9**|**GND**|Discrete output 4 (ground)
111 -|**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V)
112 -|**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V)
113 -|**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V)
114 -|**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V)
115 -|**14**|**-**|-
116 -|**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA)
117 -|**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA)
118 -|**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA)
119 -|**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA)
120 -
121 -=== Х8 – header for temperature sensors ===
122 -
123 -[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
124 -
125 -|**Pin**|**Name**|**Description**
126 -|**1**|**TEMPG1**|Ground of the thermistor 1
127 -|**2**|**TEMPG2**|Ground of the thermistor 2
128 -|**3**|**TEMP1**|Signal from the thermistor 1
129 -|**4**|**TEMP2**|Signal from the thermistor 2
130 -
131 131  
1734355584041-898.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -12.0 KB
Content
1734355584043-416.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -24.8 KB
Content