Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.BMS Main X.WebHome
1 +Battery management systems.BMS Main X.WebHome
Content
... ... @@ -1,6 +1,22 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 +== Safety rules ==
5 +
6 +To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor **able to break the load and charge circuits must be connected to the BMS.
7 +
8 +Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 +
10 +(% class="box errormessage" %)
11 +(((
12 +The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 +)))
14 +
15 +(% class="box errormessage" %)
16 +(((
17 +The system is not designed to operate with batteries whose total voltage exceeds 1000 V.
18 +)))
19 +
4 4  == Installation ==
5 5  
6 6  The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water.
... ... @@ -31,6 +31,8 @@
31 31  
32 32  === Х1 – header for power supply ===
33 33  
50 +Receptacle Housing: Molex 436450200. Terminals: Molex 43030
51 +
34 34  [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]]
35 35  
36 36  |**Pin**|**Name**|**Description**
... ... @@ -41,6 +41,8 @@
41 41  
42 42  === X3 – header for CAN (INT) interface ===
43 43  
62 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
63 +
44 44  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
45 45  
46 46  |**Pin**|**Name**|**Description**
... ... @@ -51,6 +51,8 @@
51 51  
52 52  === Х4 – header for RS-485 interface ===
53 53  
74 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
75 +
54 54  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
55 55  
56 56  |**Pin**|**Name**|**Description**
... ... @@ -67,6 +67,8 @@
67 67  
68 68  === Х5 – header for CAN (EXT) interface ===
69 69  
92 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
93 +
70 70  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
71 71  
72 72  |**Pin**|**Name**|**Description**
... ... @@ -83,6 +83,8 @@
83 83  
84 84  === Х6 – header for sold-state relays ===
85 85  
110 +Receptacle Housing: Molex 430250600. Terminals: Molex 43030
111 +
86 86  [[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]]
87 87  
88 88  |**Pin**|**Name**|**Description**
... ... @@ -95,8 +95,10 @@
95 95  
96 96  === X7 – header for discrete inputs/outputs ===
97 97  
98 -[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="80" width="263"]]
124 +Receptacle Housing: Molex 430251800. Terminals: Molex 43030
99 99  
126 +[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]]
127 +
100 100  |**Pin**|**Name**|**Description**
101 101  |**1**|**GND**|Discrete input 1 “dry contact” (ground)
102 102  |**2**|**GND**|Discrete input 2 “dry contact” (ground)
... ... @@ -119,6 +119,8 @@
119 119  
120 120  === Х8 – header for temperature sensors ===
121 121  
150 +Receptacle Housing: Molex 430250400. Terminals: Molex 43030
151 +
122 122  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
123 123  