Changes for page 2. Installation and connection
Last modified by Admin on 2025/03/18 12:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main X.WebHome1 +Battery management systems.BMS Main X.WebHome - Content
-
... ... @@ -20,6 +20,7 @@ 20 20 )))|105 × 115 × 15 21 21 |Mounting dimensions (length × width), mm|99 × 109 22 22 |Mounting holes|M3 23 +|Headers X1, X3-X8 type|Molex series Micro-Fit 23 23 24 24 == Connection == 25 25 ... ... @@ -65,11 +65,9 @@ 65 65 66 66 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 67 67 68 -1. 69 - 70 70 === Х5 – header for CAN (EXT) interface === 71 71 72 -[[image: file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.emz]][[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]71 +[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 73 73 74 74 |**Pin**|**Name**|**Description** 75 75 |**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system) ... ... @@ -77,4 +77,56 @@ 77 77 |**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA 78 78 |**4**|**CAN_EXT_GND**|Isolated ground 79 79 79 +=== J2 – jumper for switching CAN (EXT) terminal resistor === 80 + 81 +To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure: 82 + 83 +[[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]] 84 + 85 +=== Х6 – header for sold-state relays === 86 + 87 +[[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]] 88 + 89 +|**Pin**|**Name**|**Description** 90 +|**1**|**NO1**|Normally open contact of the relay 1 91 +|**2**|**NO2**|Normally open contact of the relay 2 92 +|**3**|**NO3**|Normally open contact of the relay 3 93 +|**4**|**COM1**|Common contact of the relay 1 (55V, 2A) 94 +|**5**|**COM2**|Common contact of the relay 2 (55V, 2A) 95 +|**6**|**COM3**|Common contact of the relay 3 (55V, 2A) 96 + 97 +=== X7 – header for discrete inputs/outputs === 98 + 99 +[[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]] 100 + 101 +|**Pin**|**Name**|**Description** 102 +|**1**|**GND**|Discrete input 1 “dry contact” (ground) 103 +|**2**|**GND**|Discrete input 2 “dry contact” (ground) 104 +|**3**|**GND**|Discrete input 3 “dry contact” (ground) 105 +|**4**|**GND**|Discrete input 4 “dry contact” (ground) 106 +|**5**|**-**|- 107 +|**6**|**GND**|Discrete output 1 (ground) 108 +|**7**|**GND**|Discrete output 2 (ground) 109 +|**8**|**GND**|Discrete output 3 (ground) 110 +|**9**|**GND**|Discrete output 4 (ground) 111 +|**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V) 112 +|**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V) 113 +|**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V) 114 +|**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V) 115 +|**14**|**-**|- 116 +|**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA) 117 +|**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA) 118 +|**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA) 119 +|**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA) 120 + 121 +=== Х8 – header for temperature sensors === 122 + 123 +[[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]] 124 + 125 +|**Pin**|**Name**|**Description** 126 +|**1**|**TEMPG1**|Ground of the thermistor 1 127 +|**2**|**TEMPG2**|Ground of the thermistor 2 128 +|**3**|**TEMP1**|Signal from the thermistor 1 129 +|**4**|**TEMP2**|Signal from the thermistor 2 130 + 80 80
- 1734355584041-898.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.0 KB - Content
- 1734355584043-416.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.8 KB - Content