Last modified by Admin on 2025/03/18 12:50

From version 11.1
edited by Admin
on 2025/03/18 12:31
Change comment: There is no comment for this version
To version 6.1
edited by Admin
on 2025/02/06 11:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,22 +1,6 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== Safety rules ==
5 -
6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor **able to break the load and charge circuits must be connected to the BMS.
7 -
8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 -
10 -(% class="box warningmessage" %)
11 -(((
12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 -)))
14 -
15 -(% class="box errormessage" %)
16 -(((
17 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.**
18 -)))
19 -
20 20  == Installation ==
21 21  
22 22  The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water.
... ... @@ -36,6 +36,7 @@
36 36  )))|105 × 115 × 15
37 37  |Mounting dimensions (length × width), mm|99 × 109
38 38  |Mounting holes|M3
23 +|Headers X1, X3-X8 type|Molex series Micro-Fit
39 39  
40 40  == Connection ==
41 41  
... ... @@ -47,8 +47,6 @@
47 47  
48 48  === Х1 – header for power supply ===
49 49  
50 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
51 -
52 52  [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]]
53 53  
54 54  |**Pin**|**Name**|**Description**
... ... @@ -59,8 +59,6 @@
59 59  
60 60  === X3 – header for CAN (INT) interface ===
61 61  
62 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
63 -
64 64  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
65 65  
66 66  |**Pin**|**Name**|**Description**
... ... @@ -71,8 +71,6 @@
71 71  
72 72  === Х4 – header for RS-485 interface ===
73 73  
74 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
75 -
76 76  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
77 77  
78 78  |**Pin**|**Name**|**Description**
... ... @@ -89,8 +89,6 @@
89 89  
90 90  === Х5 – header for CAN (EXT) interface ===
91 91  
92 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
93 -
94 94  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
95 95  
96 96  |**Pin**|**Name**|**Description**
... ... @@ -107,8 +107,6 @@
107 107  
108 108  === Х6 – header for sold-state relays ===
109 109  
110 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
111 -
112 112  [[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]]
113 113  
114 114  |**Pin**|**Name**|**Description**
... ... @@ -121,8 +121,6 @@
121 121  
122 122  === X7 – header for discrete inputs/outputs ===
123 123  
124 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
125 -
126 126  [[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]]
127 127  
128 128  |**Pin**|**Name**|**Description**
... ... @@ -147,8 +147,6 @@
147 147  
148 148  === Х8 – header for temperature sensors ===
149 149  
150 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
151 -
152 152  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
153 153  
154 154  |**Pin**|**Name**|**Description**