Last modified by Admin on 2025/03/18 12:50

From version 10.1
edited by Admin
on 2025/03/18 12:23
Change comment: There is no comment for this version
To version 5.2
edited by Admin
on 2024/12/19 11:15
Change comment: Update document after refactoring.

Summary

Details

Page properties
Content
... ... @@ -1,22 +1,6 @@
1 1  (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 2  = Installation and connection =
3 3  
4 -== Safety rules ==
5 -
6 -To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, at least one contactor able to break the load and charge circuits must be connected to the BMS.
7 -
8 -Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9 -
10 -(% class="box warningmessage" %)
11 -(((
12 -The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 -)))
14 -
15 -(% class="box errormessage" %)
16 -(((
17 -**The system is not designed to operate with batteries whose total voltage exceeds 1200 V.**
18 -)))
19 -
20 20  == Installation ==
21 21  
22 22  The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water.
... ... @@ -47,8 +47,6 @@
47 47  
48 48  === Х1 – header for power supply ===
49 49  
50 -Receptacle Housing: Molex 436450200. Terminals: Molex 43030
51 -
52 52  [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]]
53 53  
54 54  |**Pin**|**Name**|**Description**
... ... @@ -59,8 +59,6 @@
59 59  
60 60  === X3 – header for CAN (INT) interface ===
61 61  
62 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
63 -
64 64  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
65 65  
66 66  |**Pin**|**Name**|**Description**
... ... @@ -71,8 +71,6 @@
71 71  
72 72  === Х4 – header for RS-485 interface ===
73 73  
74 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
75 -
76 76  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
77 77  
78 78  |**Pin**|**Name**|**Description**
... ... @@ -89,8 +89,6 @@
89 89  
90 90  === Х5 – header for CAN (EXT) interface ===
91 91  
92 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
93 -
94 94  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
95 95  
96 96  |**Pin**|**Name**|**Description**
... ... @@ -107,8 +107,6 @@
107 107  
108 108  === Х6 – header for sold-state relays ===
109 109  
110 -Receptacle Housing: Molex 430250600. Terminals: Molex 43030
111 -
112 112  [[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]]
113 113  
114 114  |**Pin**|**Name**|**Description**
... ... @@ -121,8 +121,6 @@
121 121  
122 122  === X7 – header for discrete inputs/outputs ===
123 123  
124 -Receptacle Housing: Molex 430251800. Terminals: Molex 43030
125 -
126 126  [[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]]
127 127  
128 128  |**Pin**|**Name**|**Description**
... ... @@ -147,8 +147,6 @@
147 147  
148 148  === Х8 – header for temperature sensors ===
149 149  
150 -Receptacle Housing: Molex 430250400. Terminals: Molex 43030
151 -
152 152  [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
153 153  
154 154  |**Pin**|**Name**|**Description**