Wiki source code of 2. Installation and connection

Last modified by Admin on 2025/03/18 12:50

Show last authors
1 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 = Installation and connection =
3
4 == Safety rules ==
5
6 To perform the protection functions, the BMS must be able to disconnect the battery from the load and charger. To do this, **at least one contactor **able to break the load and charge circuits must be connected to the BMS.
7
8 Before use, **configure the system**. Proper operation of the BMS is possible only if it is correctly configured.
9
10 (% class="box errormessage" %)
11 (((
12 The BMS can be connected to batteries with life-threatening and health-hazardous voltage levels. When working with high-voltage batteries, observe electrical safety regulations, use safety glasses, protective clothing, insulated tools and appliances. To prevent the damage of device avoid electrostatic discharges while working with the battery.
13 )))
14
15 (% class="box errormessage" %)
16 (((
17 The system is not designed to operate with batteries whose total voltage exceeds 1000 V.
18 )))
19
20 == Installation ==
21
22 The mounting area of the BMS Main X must be protected from mechanical particles (dust, dirt, large objects) and water.
23
24 The installation site must provide convenient access for subsequent connection to the device’s headers for connecting other system elements: contactors, temperature sensors, etc.
25
26 Overall and mounting dimensions of the BMS Main X are shown below.
27
28 [[image:1734355103230-973.png||data-xwiki-image-style-alignment="center" height="460" width="450"]]
29 [[image:1734355103237-284.png||data-xwiki-image-style-alignment="center" height="207" width="450"]]
30
31 |(((
32 **Parameter**
33 )))|**Value **
34 |(((
35 Overall dimensions (length × width × height), mm
36 )))|105 × 115 × 15
37 |Mounting dimensions (length × width), mm|99 × 109
38 |Mounting holes|M3
39
40 == Connection ==
41
42 === Headers ===
43
44 There are names and locations of the BMS Main X headers in figure below.
45
46 [[image:1734355208744-833.png||data-xwiki-image-style-alignment="center" height="491" width="450"]]
47
48 === Х1 – header for power supply ===
49
50 Receptacle Housing: Molex 436450200. Terminals: Molex 43030
51
52 [[image:1734355208747-667.png||data-xwiki-image-style-alignment="center"]]
53
54 |**Pin**|**Name**|**Description**
55 |**1**|**V+**|Supply voltage 18÷36V
56 |**2**|**GND**|Ground
57
58 === X2 – header for USB ===
59
60 === X3 – header for CAN (INT) interface ===
61
62 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
63
64 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
65
66 |**Pin**|**Name**|**Description**
67 |**1**|**СAN_INT_H**|CAN-H line of the internal CAN bus (communication with battery modules)
68 |**2**|**CAN_INT_L**|CAN-L line of the internal CAN bus (communication with battery modules)
69 |**3**|**CAN_INT_5V**|Isolated 5V power supply for internal devices, max 200 mA
70 |**4**|**CAN_INT_GND**|Isolated ground
71
72 === Х4 – header for RS-485 interface ===
73
74 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
75
76 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
77
78 |**Pin**|**Name**|**Description**
79 |**1**|**RS485_A**|A line of the external RS-485 bus
80 |**2**|**RS485_B**|B line of the external RS-485 bus
81 |**3**|**-**|-
82 |**4**|**RS485_GND**|Isolated ground
83
84 === J1 – jumper for switching RS-485 terminal resistor ===
85
86 To connect the terminal resistor between the** RS485_A** and **RS485_B** lines, install the jumper J1 according to the following figure:
87
88 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]]
89
90 === Х5 – header for CAN (EXT) interface ===
91
92 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
93
94 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
95
96 |**Pin**|**Name**|**Description**
97 |**1**|**СAN_EXT_H**|CAN-H line of the external CAN bus (communication with a top-level system)
98 |**2**|**CAN_EXT_L**|CAN-L line of the external CAN bus (communication with a top-level system)
99 |**3**|**CAN_EXT_5V**|Isolated 5V power supply for external devices, max 200 mA
100 |**4**|**CAN_EXT_GND**|Isolated ground
101
102 === J2 – jumper for switching CAN (EXT) terminal resistor ===
103
104 To connect the terminal resistor between the** CAN_EXT_H** and **CAN_EXT_L** lines, install the jumper J2 according to the following figure:
105
106 [[image:1734355346488-798.png||data-xwiki-image-style-alignment="center"]]
107
108 === Х6 – header for sold-state relays ===
109
110 Receptacle Housing: Molex 430250600. Terminals: Molex 43030
111
112 [[image:1734355584041-898.jpeg||data-xwiki-image-style-alignment="center" height="65" width="90"]]
113
114 |**Pin**|**Name**|**Description**
115 |**1**|**NO1**|Normally open contact of the relay 1
116 |**2**|**NO2**|Normally open contact of the relay 2
117 |**3**|**NO3**|Normally open contact of the relay 3
118 |**4**|**COM1**|Common contact of the relay 1 (55V, 2A)
119 |**5**|**COM2**|Common contact of the relay 2 (55V, 2A)
120 |**6**|**COM3**|Common contact of the relay 3 (55V, 2A)
121
122 === X7 – header for discrete inputs/outputs ===
123
124 Receptacle Housing: Molex 430251800. Terminals: Molex 43030
125
126 [[image:1734355584043-416.jpeg||data-xwiki-image-style-alignment="center" height="79" width="260"]]
127
128 |**Pin**|**Name**|**Description**
129 |**1**|**GND**|Discrete input 1 “dry contact” (ground)
130 |**2**|**GND**|Discrete input 2 “dry contact” (ground)
131 |**3**|**GND**|Discrete input 3 “dry contact” (ground)
132 |**4**|**GND**|Discrete input 4 “dry contact” (ground)
133 |**5**|**-**|-
134 |**6**|**GND**|Discrete output 1 (ground)
135 |**7**|**GND**|Discrete output 2 (ground)
136 |**8**|**GND**|Discrete output 3 (ground)
137 |**9**|**GND**|Discrete output 4 (ground)
138 |**10**|**D_IN1**|Discrete input 1 “dry contact” (+5V)
139 |**11**|**D_IN2**|Discrete input 2 “dry contact” (+5V)
140 |**12**|**D_IN3**|Discrete input 3 “dry contact” (+5V)
141 |**13**|**D_IN4**|Discrete input 4 “dry contact” (+5V)
142 |**14**|**-**|-
143 |**15**|**D_OUT1**|Discrete output 1 (+5V, 20mA)
144 |**16**|**D_OUT2**|Discrete output 2 (+5V, 20mA)
145 |**17**|**D_OUT3**|Discrete output 3 (+5V, 20mA)
146 |**18**|**D_OUT4**|Discrete output 4 (+5V, 20mA)
147
148 === Х8 – header for temperature sensors ===
149
150 Receptacle Housing: Molex 430250400. Terminals: Molex 43030
151
152 [[image:1734355229969-197.png||data-xwiki-image-style-alignment="center"]]
153
154 |**Pin**|**Name**|**Description**
155 |**1**|**TEMPG1**|Ground of the thermistor 1
156 |**2**|**TEMPG2**|Ground of the thermistor 2
157 |**3**|**TEMP1**|Signal from the thermistor 1