Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -174,7 +174,7 @@ 174 174 175 175 The battery charge management is configured in the "Control → Charge" section: 176 176 177 -[[image:173 4089684907-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="600"]]177 +[[image:1738081025199-282.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]] 178 178 179 179 In this section: 180 180 ... ... @@ -187,16 +187,13 @@ 187 187 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 188 188 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 189 189 * Checking voltages time – a time of checking voltages of battery modules, millisecond; 190 -* Pre-balancing modules time – a time of pre-charging battery modules, millisecond; 191 191 * Balancing modules time – a time of balancing battery modules, millisecond; 192 192 * Control the precharging contactor – a flag to control the main precharging contactor; 193 -* Precharging time – a time of precharging, millisecond; 194 194 * Canceling charging time – a delay before opening the main charging contactor, ms; 195 -* Limit module current – a flag that allows to limit the charging current of a modular battery so that the current of each battery module does not exceed its maximum allowable charge current; 196 -* Slew rate – a rate of change of the charge current limit when the “Limit module current” flag is set, A/s; 197 197 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 198 198 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 199 199 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 196 +* Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 200 200 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 201 201 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 202 202 * Errors 1 (2) to open the charging contactor – errors that cause the main charging contactor "Charging" to open; ... ... @@ -239,7 +239,7 @@ 239 239 240 240 The battery discharge management is configured in the "Control → Discharge" section: 241 241 242 -[[image:173 4089702987-534.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="179" width="600"]]239 +[[image:1738081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]] 243 243 244 244 In this section: 245 245 ... ... @@ -252,16 +252,13 @@ 252 252 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 253 253 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 254 254 * Checking voltages time – a time of checking voltages of battery modules, millisecond; 255 -* Pre-balancing modules time – a time of precharging battery modules, millisecond; 256 256 * Balancing modules time – a time of balancing battery modules, millisecond; 257 257 * Control the precharging contactor – a flag to control the main precharging contactor; 258 -* Precharging time – a time of precharging, millisecond; 259 259 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond; 260 -* Limit module current – a flag that allows to limit the discharging current of a modular battery so that the current of each battery module does not exceed its maximum allowable discharge current; 261 -* Slew rate – a rate of change of the discharge current limit when the “Limit module current” flag is set, A/s; 262 262 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 263 263 * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 264 264 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 258 +* Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 265 265 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 266 266 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 267 267 * Errors 1 (2) to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open,
- 1738081025199-282.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.3 KB - Content
- 1738081173083-894.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +49.1 KB - Content