Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -110,27 +110,13 @@ 110 110 111 111 To change the precharge parameters, select the section “Control → Precharge”: 112 112 113 +[[image:1734089664376-736.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="56" width="600"]] 114 + 113 113 In this section: 114 114 115 - 116 116 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 117 117 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 118 -* Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V; 119 -* Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 120 -* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 121 -* Relaxation between attempts – a duration between precharge attempts, millisecond; 122 -* Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; 123 -* Precharge resistor resistance, Ohm; 124 -* Maximum allowable power dissipated in the resistor, W; 125 -* Delay before setting the "Precharge error" when checking power, millisecond; 126 -* Delay before clearing the "Precharge error", second; 127 -* Lock the "Precharge error" – a flag to block the error until the device is restarted. 128 -* ((( 129 -“Precharge error” generation conditions: 130 -))) 131 -* the precharge current does not decrease after "Number of precharging attempts"; 132 -* voltages before and after contactors are not equal after "Number of precharging attempts"; 133 -* power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 119 +* Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V. 134 134 135 135 === Charge === 136 136
- 1738080762857-975.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -36.0 KB - Content