Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -110,7 +110,7 @@ 110 110 111 111 To change the precharge parameters, select the section “Control → Precharge”: 112 112 113 -In this section: 113 +[[image:1738080762857-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="600"]]In this section: 114 114 115 115 116 116 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; ... ... @@ -125,13 +125,18 @@ 125 125 * Delay before setting the "Precharge error" when checking power, millisecond; 126 126 * Delay before clearing the "Precharge error", second; 127 127 * Lock the "Precharge error" – a flag to block the error until the device is restarted. 128 - * (((128 + 129 129 “Precharge error” generation conditions: 130 - )))130 + 131 131 * the precharge current does not decrease after "Number of precharging attempts"; 132 132 * voltages before and after contactors are not equal after "Number of precharging attempts"; 133 133 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 134 134 135 +(% class="box warningmessage" %) 136 +((( 137 +Behavior of contactors at “Precharge error” is configured in corresponding contactor settings! 138 +))) 139 + 135 135 === Charge === 136 136 137 137 The BMS Main 3X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit. ... ... @@ -169,7 +169,7 @@ 169 169 170 170 The battery charge management is configured in the "Control → Charge" section: 171 171 172 -[[image:173 4089684907-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="600"]]177 +[[image:1738081025199-282.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]] 173 173 174 174 In this section: 175 175 ... ... @@ -182,16 +182,13 @@ 182 182 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 183 183 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 184 184 * Checking voltages time – a time of checking voltages of battery modules, millisecond; 185 -* Pre-balancing modules time – a time of pre-charging battery modules, millisecond; 186 186 * Balancing modules time – a time of balancing battery modules, millisecond; 187 187 * Control the precharging contactor – a flag to control the main precharging contactor; 188 -* Precharging time – a time of precharging, millisecond; 189 189 * Canceling charging time – a delay before opening the main charging contactor, ms; 190 -* Limit module current – a flag that allows to limit the charging current of a modular battery so that the current of each battery module does not exceed its maximum allowable charge current; 191 -* Slew rate – a rate of change of the charge current limit when the “Limit module current” flag is set, A/s; 192 192 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 193 193 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 194 194 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 196 +* Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 195 195 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 196 196 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 197 197 * Errors 1 (2) to open the charging contactor – errors that cause the main charging contactor "Charging" to open;
- 1738080762857-975.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.0 KB - Content
- 1738081025199-282.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.3 KB - Content