Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -110,14 +110,33 @@ 110 110 111 111 To change the precharge parameters, select the section “Control → Precharge”: 112 112 113 -[[image:173 4089664376-736.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="56" width="600"]]113 +[[image:1738080762857-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="600"]]In this section: 114 114 115 -In this section: 116 116 117 117 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 118 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 119 -* Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V. 118 +* Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V; 119 +* Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 120 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 121 +* Relaxation between attempts – a duration between precharge attempts, millisecond; 122 +* Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; 123 +* Precharge resistor resistance, Ohm; 124 +* Maximum allowable power dissipated in the resistor, W; 125 +* Delay before setting the "Precharge error" when checking power, millisecond; 126 +* Delay before clearing the "Precharge error", second; 127 +* Lock the "Precharge error" – a flag to block the error until the device is restarted. 120 120 129 +“Precharge error” generation conditions: 130 + 131 +* the precharge current does not decrease after "Number of precharging attempts"; 132 +* voltages before and after contactors are not equal after "Number of precharging attempts"; 133 +* power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 134 + 135 +(% class="box warningmessage" %) 136 +((( 137 +Behavior of contactors at “Precharge error” is configured in corresponding contactor settings! 138 +))) 139 + 121 121 === Charge === 122 122 123 123 The BMS Main 3X device manages the parallel connection of the battery modules and the connection of the battery to the charging circuit. ... ... @@ -155,7 +155,7 @@ 155 155 156 156 The battery charge management is configured in the "Control → Charge" section: 157 157 158 -[[image:173 4089684907-463.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="180" width="600"]]177 +[[image:1738081025199-282.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]] 159 159 160 160 In this section: 161 161 ... ... @@ -168,16 +168,13 @@ 168 168 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 169 169 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 170 170 * Checking voltages time – a time of checking voltages of battery modules, millisecond; 171 -* Pre-balancing modules time – a time of pre-charging battery modules, millisecond; 172 172 * Balancing modules time – a time of balancing battery modules, millisecond; 173 173 * Control the precharging contactor – a flag to control the main precharging contactor; 174 -* Precharging time – a time of precharging, millisecond; 175 175 * Canceling charging time – a delay before opening the main charging contactor, ms; 176 -* Limit module current – a flag that allows to limit the charging current of a modular battery so that the current of each battery module does not exceed its maximum allowable charge current; 177 -* Slew rate – a rate of change of the charge current limit when the “Limit module current” flag is set, A/s; 178 178 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 179 179 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 180 180 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 196 +* Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 181 181 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 182 182 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 183 183 * Errors 1 (2) to open the charging contactor – errors that cause the main charging contactor "Charging" to open;
- 1738080762857-975.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.0 KB - Content
- 1738081025199-282.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +48.3 KB - Content