Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 6.5
edited by Admin
on 2025/01/28 16:09
Change comment: There is no comment for this version
To version 6.4
edited by Admin
on 2025/01/28 16:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -55,12 +55,13 @@
55 55  The Main contactor algorithm supports the following modes:
56 56  
57 57  * Always on;
58 -* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
58 +* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors.
59 59  
60 60  In “Always on” mode, the main contactor closes if all the following is true:
61 61  
62 62  * “Charging” contactor is open;
63 63  * “Discharging” contactor is open;
64 +
64 64  * there are no errors.
65 65  
66 66  In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true: