... ... @@ -55,13 +55,12 @@
55 55  The Main contactor algorithm supports the following modes:
56 56  
57 57  * Always on;
58 -* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors.
58 +* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
59 59  
60 60  In “Always on” mode, the main contactor closes if all the following is true:
61 61  
62 62  * “Charging” contactor is open;
63 63  * “Discharging” contactor is open;
64 -
65 65  * there are no errors.
66 66  
67 67  In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true: