Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -40,14 +40,14 @@ 40 40 41 41 * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules; 42 42 * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules; 43 -* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules. 43 +* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum health); 44 +* Max-Min SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (optimized for maximum capacity, recommended); 44 44 45 45 Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported: 46 46 47 47 * Minimal SOH – SOH of the modular battery is assumed to be the minimum SOH among the battery modules; 49 +* Average SOH – SOH of the modular battery is taken equal to the arithmetic average of the SOH of the battery modules. 48 48 49 -Average SOH – SOH of the modular battery is taken equal to the arithmetic average of the SOH of the battery modules. 50 - 51 51 === Main contactor === 52 52 53 53 The BMS Main 3X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.