... ... @@ -26,7 +26,6 @@
26 26  
27 27  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings.
28 28  
29 -You can set up maximum number of found modules to finish initialization in corresponding section.
30 30  
31 31  === Calculation of battery parameters ===
32 32  
... ... @@ -40,7 +40,7 @@
40 40  
41 41  * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules;
42 42  * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules;
43 -* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules.
42 +* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (recommended).
44 44  
45 45  Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported:
46 46  
... ... @@ -141,7 +141,7 @@
141 141  1. Checking intermodular balancing currents (the duration of the check is set in the settings). If there is no current unbalance (“Current unbalance (CH)”) or errors are ignored (“Always on”), go to step 6, otherwise open all charging contactors, and go to step 1.
142 142  1. The battery modules are joined. If the “Join to charge” request is cleared or the "Charging current unbalance" error occurs, go to step 1.
143 143  
144 -The operation of** closing main charging contactor** is described in the following steps:
143 +The operation of** closing main charging contactor** is described in the following steps:
145 145  
146 146  1. The main charging contactor “Charging” is open. When the “Charge request” is received, the voltage and current unbalance errors (“Voltage unbalance (CH)”, “Current unbalance (CH)”, “Charging current unbalance”) are cleared, and the battery modules are joined, go to step 2.
147 147  1. Closing the main precharging contactor “Precharging” (optional). Go to step 3.
... ... @@ -394,7 +394,7 @@
394 394  
395 395  To configure the parameters for counting the number of contactor openings, select the section “Control → Load open counter”:
396 396  
397 -[[image:1734089726360-887.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="600"]]
396 +[[image:1734089726360-887.png]]
398 398  
399 399  In this section: