Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 6.2
edited by Admin
on 2024/12/13 12:40
Change comment: Update document after refactoring.
To version 6.3
edited by Admin
on 2025/01/28 16:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -26,6 +26,8 @@
26 26  
27 27  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings.
28 28  
29 +You can set up maximum number of found modules to finish initialization in corresponding section.
30 +
29 29  === Calculation of battery parameters ===
30 30  
31 31  The BMS Main 3X device calculates battery parameters based on user settings.
... ... @@ -38,7 +38,7 @@
38 38  
39 39  * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules;
40 40  * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules;
41 -* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (recommended).
43 +* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules.
42 42  
43 43  Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported:
44 44