... ... @@ -4,16 +4,15 @@
4 4  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Control ==
6 6  
7 -=== Initialization ===
7 +=== General parameters ===
8 8  
9 -Initialization parameters of BMS Main 3X are configured in the «Control → Initialization» section:
9 +General parameters of BMS Main 3X are configured in the «Control → General» section:
10 10  
11 11  [[image:1734023979572-693.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="79" width="600"]]
12 12  
13 13  In this section:
14 14  
15 -* Minimum numb
16 -* Device initialization delay after modules are initialized – a delay before processing functions after finishing device initialization (initialization includes current sensors calibration and battery modules search), millisecond.
15 +* Initialization delay – a delay before processing functions after finishing device initialization (initialization includes current sensors calibration and battery modules search), millisecond.
17 17  
18 18  === Battery modules ===
19 19  
... ... @@ -21,9 +21,11 @@
21 21  
22 22  Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section:
23 23  
24 -[[image:1743089636435-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="600"]]
23 +
24 +[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]]
25 25  The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”:
26 26  
27 +
27 27  [[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]]
28 28  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings.
29 29  
... ... @@ -177,7 +177,7 @@
177 177  
178 178  The battery charge management is configured in the "Control → Charge" section:
179 179  
180 -[[image:1744733920147-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]]
181 +[[image:1742473171584-412.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]]
181 181  
182 182  In this section:
183 183  
... ... @@ -190,8 +190,7 @@
190 190  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
191 191  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
192 192  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
193 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
194 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
194 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
195 195  * Control the precharging contactor – a flag to control the main precharging contactor;
196 196  * Canceling charging time – a delay before opening the main charging contactor, ms;
197 197  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
... ... @@ -198,7 +198,7 @@
198 198  * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared;
199 199  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
200 200  * Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
201 -* Regulator: Gain – a gain of current regulator;
201 +* Regulator: Gain – a gain of current regulato
202 202  * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A;
203 203  * Maximum charge current limit – a maximum allowed charging current of all battery, A;
204 204  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -242,7 +242,7 @@
242 242  
243 243  The battery discharge management is configured in the "Control → Discharge" section:
244 244  
245 -[[image:1744735777632-647.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="600"]]
245 +[[image:1738081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]]
246 246  
247 247  In this section:
248 248  
... ... @@ -255,15 +255,12 @@
255 255  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
256 256  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
257 257  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
258 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
259 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
258 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
260 260  * Control the precharging contactor – a flag to control the main precharging contactor;
261 261  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
262 262  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
263 263  * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared;
264 264  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
265 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
266 -* Regulator: Gain – a gain of current regulator;
267 267  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
268 268  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
269 269  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -312,7 +312,7 @@
312 312  
313 313  The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section:
314 314  
315 -[[image:1744735816351-271.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="249" width="600"]]
312 +[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]]
316 316  
317 317  In this section:
318 318  
... ... @@ -328,8 +328,7 @@
328 328  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
329 329  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
330 330  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
331 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging/discharging contactor, millisecond;
332 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
328 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
333 333  * Control the precharging contactor – a flag to control the main precharging contactor;
334 334  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
335 335  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared;
... ... @@ -336,8 +336,6 @@
336 336  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared;
337 337  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
338 338  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
339 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
340 -* Regulator: Gain – a gain of current regulator;
341 341  * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A;
342 342  * Maximum charge current limit – a maximum allowed charging current of all the battery, A;
343 343  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
1742475784289-921.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -62.8 KB
Content
1742475800208-207.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -73.3 KB
Content
1743089636435-519.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -30.2 KB
Content
1744733920147-654.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -53.6 KB
Content
1744735701575-567.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -54.5 KB