Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -328,7 +328,7 @@ 328 328 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 329 329 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 330 330 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 331 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main chardischarging contactor, millisecond; 331 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging/discharging contactor, millisecond; 332 332 * Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 333 333 * Control the precharging contactor – a flag to control the main precharging contactor; 334 334 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;