... ... @@ -176,7 +176,7 @@ 176 176 177 177 The battery charge management is configured in the "Control → Charge" section: 178 178 179 -[[image:174473 3920147-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]]179 +[[image:1742473171584-412.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]] 180 180 181 181 In this section: 182 182 ... ... @@ -189,8 +189,7 @@ 189 189 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 190 190 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 191 191 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 192 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 193 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 192 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 194 194 * Control the precharging contactor – a flag to control the main precharging contactor; 195 195 * Canceling charging time – a delay before opening the main charging contactor, ms; 196 196 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. ... ... @@ -254,8 +254,7 @@ 254 254 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 255 255 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 256 256 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 257 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 258 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 256 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 259 259 * Control the precharging contactor – a flag to control the main precharging contactor; 260 260 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond; 261 261 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. ... ... @@ -328,8 +328,7 @@ 328 328 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 329 329 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 330 330 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 331 -* Module balancing time – a time of balancing battery modules after joining modules and before closing main chardischarging contactor, millisecond; 332 -* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined; 329 +* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond; 333 333 * Control the precharging contactor – a flag to control the main precharging contactor; 334 334 * Canceling discharging time – a delay before opening the main discharging contactor, millisecond; 335 335 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared;
- 1744733920147-654.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -53.6 KB - Content