... ... @@ -190,7 +190,7 @@
190 190  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
191 191  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
192 192  * Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond;
193 -* Interrupt balancing when modules are joined – a flag to start closing
193 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
194 194  * Control the precharging contactor – a flag to control the main precharging contactor;
195 195  * Canceling charging time – a delay before opening the main charging contactor, ms;
196 196  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
... ... @@ -241,7 +241,7 @@
241 241  
242 242  The battery discharge management is configured in the "Control → Discharge" section:
243 243  
244 -[[image:1742473693993-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]]
244 +[[image:1744735777632-647.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="600"]]
245 245  
246 246  In this section:
247 247  
... ... @@ -254,7 +254,8 @@
254 254  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
255 255  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
256 256  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
257 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
257 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
258 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
258 258  * Control the precharging contactor – a flag to control the main precharging contactor;
259 259  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
260 260  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
... ... @@ -327,7 +327,8 @@
327 327  * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A;
328 328  * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V;
329 329  * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond;
330 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main discharging contactor, millisecond;
331 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging/discharging contactor, millisecond;
332 +* Interrupt balancing when modules are joined – a flag to break balancing time after all modules are joined;
331 331  * Control the precharging contactor – a flag to control the main precharging contactor;
332 332  * Canceling discharging time – a delay before opening the main discharging contactor, millisecond;
333 333  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared;
1744735701575-567.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +54.5 KB
Content
1744735777632-647.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +54.5 KB
Content
1744735816351-271.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +62.5 KB
Content