Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,9 +20,11 @@ 20 20 21 21 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 22 22 23 -[[image:1743089636435-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="600"]] 23 + 24 +[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]] 24 24 The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”: 25 25 27 + 26 26 [[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]] 27 27 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 28 28 ... ... @@ -196,7 +196,7 @@ 196 196 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 197 197 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 198 198 * Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 199 -* Regulator: Gain – a gain of current regulato r;201 +* Regulator: Gain – a gain of current regulato 200 200 * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 201 201 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 202 202 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -240,7 +240,7 @@ 240 240 241 241 The battery discharge management is configured in the "Control → Discharge" section: 242 242 243 -[[image:17 42473693993-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]]245 +[[image:1738081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]] 244 244 245 245 In this section: 246 246 ... ... @@ -259,8 +259,6 @@ 259 259 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 260 260 * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 261 261 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 262 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 263 -* Regulator: Gain – a gain of current regulator; 264 264 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 265 265 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 266 266 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -309,9 +309,8 @@ 309 309 310 310 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 311 311 312 +[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]] 312 312 313 -[[image:1742475800208-207.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]] 314 - 315 315 In this section: 316 316 317 317 * Enable – a flag to enable battery charge/discharge controller; ... ... @@ -333,8 +333,6 @@ 333 333 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared; 334 334 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 335 335 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 336 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 337 -* Regulator: Gain – a gain of current regulator; 338 338 * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A; 339 339 * Maximum charge current limit – a maximum allowed charging current of all the battery, A; 340 340 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
- 1742475784289-921.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -62.8 KB - Content
- 1742475800208-207.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -73.3 KB - Content
- 1743089636435-519.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -30.2 KB - Content