Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 3X.3\. Configuration.WebHome1 +Battery management systems.BMS Main 3X.3\. Configuration.WebHome - Content
-
... ... @@ -26,6 +26,7 @@ 26 26 27 27 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 28 28 29 +You can set up maximum number of found modules to finish initialization in corresponding section. 29 29 30 30 === Calculation of battery parameters === 31 31 ... ... @@ -39,7 +39,7 @@ 39 39 40 40 * Minimal SOC – SOC of the modular battery is assumed to be the minimum SOC among the battery modules; 41 41 * Average SOC – SOC of the modular battery is taken equal to the arithmetic average of the SOC of the battery modules; 42 -* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules (recommended).43 +* Min-Max SOC – SOC of the modular battery is calculated based on the minimal and maximum SOC of the battery modules. 43 43 44 44 Calculation of the battery state of health (SOH) is configured in the "Control → Calculation → Final SOH" section. The following battery SOH calculation methods are supported: 45 45 ... ... @@ -140,7 +140,7 @@ 140 140 1. Checking intermodular balancing currents (the duration of the check is set in the settings). If there is no current unbalance (“Current unbalance (CH)”) or errors are ignored (“Always on”), go to step 6, otherwise open all charging contactors, and go to step 1. 141 141 1. The battery modules are joined. If the “Join to charge” request is cleared or the "Charging current unbalance" error occurs, go to step 1. 142 142 143 -The operation of** 144 +The operation of** closing main charging contactor** is described in the following steps: 144 144 145 145 1. The main charging contactor “Charging” is open. When the “Charge request” is received, the voltage and current unbalance errors (“Voltage unbalance (CH)”, “Current unbalance (CH)”, “Charging current unbalance”) are cleared, and the battery modules are joined, go to step 2. 146 146 1. Closing the main precharging contactor “Precharging” (optional). Go to step 3. ... ... @@ -393,7 +393,7 @@ 393 393 394 394 To configure the parameters for counting the number of contactor openings, select the section “Control → Load open counter”: 395 395 396 -[[image:1734089726360-887.png]] 397 +[[image:1734089726360-887.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="83" width="600"]] 397 397 398 398 In this section: 399 399