Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,11 +20,9 @@ 20 20 21 21 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 22 22 23 - 24 -[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]] 23 +[[image:1743089636435-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="600"]] 25 25 The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”: 26 26 27 - 28 28 [[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]] 29 29 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 30 30 ... ... @@ -178,7 +178,7 @@ 178 178 179 179 The battery charge management is configured in the "Control → Charge" section: 180 180 181 -[[image:174 2473171584-412.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]]179 +[[image:1744733920147-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]] 182 182 183 183 In this section: 184 184 ... ... @@ -191,7 +191,8 @@ 191 191 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 192 192 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 193 193 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 194 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 192 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 193 +* Interrupt balancing when modules are joined – a flag to start closing main charging 195 195 * Control the precharging contactor – a flag to control the main precharging contactor; 196 196 * Canceling charging time – a delay before opening the main charging contactor, ms; 197 197 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
- 1743089636435-519.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.2 KB - Content
- 1744733920147-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.6 KB - Content