197 197  * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared.
198 198  * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared;
199 199  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
200 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
201 -* Regulator: Gain – a gain of current regulator;
200 +* Regulator
202 202  * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A;
203 203  * Maximum charge current limit – a maximum allowed charging current of all battery, A;
204 204  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -261,8 +261,6 @@
261 261  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
262 262  * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared;
263 263  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
264 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
265 -* Regulator: Gain – a gain of current regulator;
266 266  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
267 267  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
268 268  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -334,8 +334,6 @@
334 334  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared;
335 335  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
336 336  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
337 -* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
338 -* Regulator: Gain – a gain of current regulator;
339 339  * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A;
340 340  * Maximum charge current limit – a maximum allowed charging current of all the battery, A;
341 341  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;