Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 35.9
edited by Admin
on 2025/03/20 13:00
Change comment: There is no comment for this version
To version 41.1
edited by Admin
on 2025/03/27 15:34
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -20,11 +20,9 @@
20 20  
21 21  Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section:
22 22  
23 -
24 -[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]]
23 +[[image:1743089636435-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="600"]]
25 25  The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”:
26 26  
27 -
28 28  [[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]]
29 29  Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings.
30 30  
... ... @@ -198,7 +198,7 @@
198 198  * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared;
199 199  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
200 200  * Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
201 -* Regulator: Gain – a gain of current regulato
199 +* Regulator: Gain – a gain of current regulator;
202 202  * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A;
203 203  * Maximum charge current limit – a maximum allowed charging current of all battery, A;
204 204  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -242,7 +242,7 @@
242 242  
243 243  The battery discharge management is configured in the "Control → Discharge" section:
244 244  
245 -[[image:1738081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]]
243 +[[image:1742473693993-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]]
246 246  
247 247  In this section:
248 248  
... ... @@ -261,6 +261,8 @@
261 261  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared.
262 262  * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared;
263 263  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
262 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
263 +* Regulator: Gain – a gain of current regulator;
264 264  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
265 265  * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A;
266 266  * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus;
... ... @@ -309,8 +309,9 @@
309 309  
310 310  The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section:
311 311  
312 -[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]]
313 313  
313 +[[image:1742475800208-207.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]]
314 +
314 314  In this section:
315 315  
316 316  * Enable – a flag to enable battery charge/discharge controller;
... ... @@ -332,6 +332,8 @@
332 332  * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared;
333 333  * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears;
334 334  * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears;
336 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit;
337 +* Regulator: Gain – a gain of current regulator;
335 335  * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A;
336 336  * Maximum charge current limit – a maximum allowed charging current of all the battery, A;
337 337  * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
1742475784289-921.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +62.8 KB
Content
1742475800208-207.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +73.3 KB
Content
1743089636435-519.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +30.2 KB
Content