Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,11 +20,9 @@ 20 20 21 21 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 22 22 23 - 24 -[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]] 23 +[[image:1743089636435-519.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="147" width="600"]] 25 25 The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”: 26 26 27 - 28 28 [[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]] 29 29 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 30 30 ... ... @@ -178,7 +178,7 @@ 178 178 179 179 The battery charge management is configured in the "Control → Charge" section: 180 180 181 -[[image:174 2473171584-412.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]]179 +[[image:1744733920147-654.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="600"]] 182 182 183 183 In this section: 184 184 ... ... @@ -191,13 +191,15 @@ 191 191 * Allowable battery current to rejoin modules – a battery current at which joining of battery modules is permitted, A; 192 192 * Allowable voltage difference to rejoin modules – a difference between the voltage of the disconnected module and the battery voltage at which its joining is permitted, V; 193 193 * Checking voltages time – a time of checking voltages of battery modules before starting joining modules, millisecond; 194 -* Balancing modules time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 192 +* Module balancing time – a time of balancing battery modules after joining modules and before closing main charging contactor, millisecond; 193 +* Interrupt balancing when modules are joined – a flag to start closing 195 195 * Control the precharging contactor – a flag to control the main precharging contactor; 196 196 * Canceling charging time – a delay before opening the main charging contactor, ms; 197 197 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 198 198 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 199 199 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 200 -* Regulator 199 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 200 +* Regulator: Gain – a gain of current regulator; 201 201 * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 202 202 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 203 203 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -241,7 +241,7 @@ 241 241 242 242 The battery discharge management is configured in the "Control → Discharge" section: 243 243 244 -[[image:17 38081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]]244 +[[image:1742473693993-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]] 245 245 246 246 In this section: 247 247 ... ... @@ -260,6 +260,8 @@ 260 260 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 261 261 * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 262 262 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 263 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 264 +* Regulator: Gain – a gain of current regulator; 263 263 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 264 264 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 265 265 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -308,8 +308,9 @@ 308 308 309 309 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 310 310 311 -[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]] 312 312 314 +[[image:1742475800208-207.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]] 315 + 313 313 In this section: 314 314 315 315 * Enable – a flag to enable battery charge/discharge controller; ... ... @@ -331,6 +331,8 @@ 331 331 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared; 332 332 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 333 333 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 337 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 338 +* Regulator: Gain – a gain of current regulator; 334 334 * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A; 335 335 * Maximum charge current limit – a maximum allowed charging current of all the battery, A; 336 336 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
- 1742475784289-921.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.8 KB - Content
- 1742475800208-207.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.3 KB - Content
- 1743089636435-519.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +30.2 KB - Content
- 1744733920147-654.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.6 KB - Content