... ... @@ -197,6 +197,8 @@ 197 197 * Disconnect modules that are not ready to charge – a flag for disconnecting modules that have the “Ready to charge” signal cleared. 198 198 * Disconnect all modules if one is not ready to charge – a flag for disconnecting all modules if any of the modules have the “Ready to charge” signal cleared; 199 199 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 200 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 201 +* Regulator: Gain – a gain of current regulator; 200 200 * Maximum CONTINUOUS charge current limit – a maximum continuous allowed charging current of all battery, A; 201 201 * Maximum charge current limit – a maximum allowed charging current of all battery, A; 202 202 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -240,7 +240,7 @@ 240 240 241 241 The battery discharge management is configured in the "Control → Discharge" section: 242 242 243 -[[image:17 38081173083-894.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="600"]]245 +[[image:1742473693993-991.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="237" width="600"]] 244 244 245 245 In this section: 246 246 ... ... @@ -259,6 +259,8 @@ 259 259 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared. 260 260 * Disconnect all modules if one is not ready to discharge – a flag for disconnecting all modules if one of the modules have the “Ready to discharge” signal cleared; 261 261 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 264 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 265 +* Regulator: Gain – a gain of current regulator; 262 262 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 263 263 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 264 264 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; ... ... @@ -307,8 +307,9 @@ 307 307 308 308 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 309 309 310 -[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]] 311 311 315 +[[image:1742475800208-207.png]] 316 + 312 312 In this section: 313 313 314 314 * Enable – a flag to enable battery charge/discharge controller; ... ... @@ -330,6 +330,8 @@ 330 330 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared; 331 331 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 332 332 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 338 +* Regulator: Keep battery module currents below limits – a flag to enable regulation of module currents to be below module current limit; 339 +* Regulator: Gain – a gain of current regulator; 333 333 * Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A; 334 334 * Maximum charge current limit – a maximum allowed charging current of all the battery, A; 335 335 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A;
- 1742475784289-921.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +62.8 KB - Content
- 1742475800208-207.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +73.3 KB - Content