Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 25.1
edited by Admin
on 2025/02/19 15:01
Change comment: Загрузить новое вложение 1739977307594-438.png
To version 23.1
edited by Admin
on 2025/02/19 14:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -110,10 +110,10 @@
110 110  
111 111  To change the precharge parameters, select the section “Control → Precharge”:
112 112  
113 -[[image:1739970002016-142.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="600"]]
114 -
115 115  In this section:
116 116  
115 +[[image:1739970002016-142.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="600"]]
116 +
117 117  * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A;
118 118  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
119 119  * Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V;
1739977307594-438.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -39.2 KB
Content