Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,15 +18,15 @@ 18 18 19 19 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 20 20 21 +[[image:1734023979582-179.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="600"]] 21 21 22 -[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]] 23 23 The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”: 24 24 25 +[[image:1734023979583-589.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="186" width="600"]] 25 25 26 -[[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]] 27 27 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 28 28 29 -In corresponding section you can set up mi nimum number of found modules to finish initialization.29 +In corresponding section you can set up maximum number of found modules to finish initialization. 30 30 31 31 === Calculation of battery parameters === 32 32 ... ... @@ -57,18 +57,18 @@ 57 57 * Always on; 58 58 * Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors. 59 59 60 -In “Always on” mode main contactor closes if all the following is true: 60 +In “Always on” mode, the main contactor closes if all the following is true: 61 61 62 -* Other contactors are open; 63 -* There are no errors from the "Errors 1, 2 ..." bitfileds. 62 +* “Charging” contactor is open; 63 +* “Discharging” contactor is open; 64 +* there are no errors. 64 64 65 -In “Always on” mode main contactor opens if a llthe following is true:66 +In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true: 66 66 67 -* Other contactors are open; 68 -* There is an error from the the "Errors 1, 2 ..." bitfileds. 68 +* “Charging current present” is set; 69 +* “Discharging current present” is set; 70 +* one or more errors persist. 69 69 70 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 71 - 72 72 To change the parameters of the main contactor, select the "Control → Main contactor" section: 73 73 74 74 [[image:1734024131196-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="94" width="600"]]