Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 22.3
edited by Admin
on 2025/02/19 14:57
Change comment: There is no comment for this version
To version 25.1
edited by Admin
on 2025/02/19 15:01
Change comment: Загрузить новое вложение 1739977307594-438.png

Summary

Details

Page properties
Content
... ... @@ -52,6 +52,11 @@
52 52  
53 53  The BMS Main 3X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.
54 54  
55 +The Main contactor algorithm supports the following modes:
56 +
57 +* Always on;
58 +* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
59 +
55 55  In “Always on” mode main contactor closes if all the following is true:
56 56  
57 57  * Other contactors are open;
... ... @@ -64,8 +64,6 @@
64 64  
65 65  In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
66 66  
67 -*
68 -
69 69  To change the parameters of the main contactor, select the "Control → Main contactor" section:
70 70  
71 71  [[image:1734024131196-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="94" width="600"]]
... ... @@ -107,10 +107,10 @@
107 107  
108 108  To change the precharge parameters, select the section “Control → Precharge”:
109 109  
110 -In this section:
111 -
112 112  [[image:1739970002016-142.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="600"]]
113 113  
115 +In this section:
116 +
114 114  * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A;
115 115  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
116 116  * Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V;
1739977307594-438.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +39.2 KB
Content