... ... @@ -52,19 +52,22 @@
52 52  
53 53  The BMS Main 3X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.
54 54  
55 -In “Always on” mode main contactor closes if all the following is true:
55 +The Main contactor algorithm supports the following modes:
56 56  
57 -* Other contactors are open;
58 -* There are no errors from the "Errors 1, 2 ..." bitfileds.
57 +* Always on;
58 +* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
59 59  
60 -In “Always on” mode main contactor opens if all the following is true:
60 +In “Always on” mode, the main contactor closes if all the following is true:
61 61  
62 -* Other contactors are open;
63 -* There is an error from the the "Errors 1, 2 ..." bitfileds.
62 +* “Charging” contactor is open;
63 +* “Discharging” contactor is open;
64 +* there are no errors.
64 64  
65 -In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
66 +In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true:
66 66  
67 -*
68 +* “Charging current present” is set;
69 +* “Discharging current present” is set;
70 +* one or more errors persist.
68 68  
69 69  To change the parameters of the main contactor, select the "Control → Main contactor" section:
70 70