Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -18,15 +18,15 @@ 18 18 19 19 Flags for enabling battery modules are configured in the "Control → Modules → Enable (modules 1 to 8)" and "Control → Modules → Enable (modules 9 to 32)" section: 20 20 21 +[[image:1734023979582-179.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="165" width="600"]] 21 21 22 -[[image:1739976358691-364.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="164" width="600"]] 23 23 The network addresses of the battery modules are configured in the "Control → Modules → Node IDs (modules 1 to 8)” and "Control → Modules → Node IDs (modules 9 to 32)”: 24 24 25 +[[image:1734023979583-589.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="186" width="600"]] 25 25 26 -[[image:1739976370994-390.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="600"]] 27 27 Each module in a battery must have a unique address. You can change the address in the battery module settings in the “Connectivity → CAN” section of the BMS Main 3 settings. 28 28 29 -In corresponding section you can set up mi nimum number of found modules to finish initialization.29 +In corresponding section you can set up maximum number of found modules to finish initialization. 30 30 31 31 === Calculation of battery parameters === 32 32 ... ... @@ -52,19 +52,22 @@ 52 52 53 53 The BMS Main 3X device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 54 54 55 - In “Always on” modemain contactorclosesif allthe followingis true:55 +The Main contactor algorithm supports the following modes: 56 56 57 -* Other contactorsareopen;58 -* There arenoerrorsfromthe"Errors1,2..."bitfileds.57 +* Always on; 58 +* Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors. 59 59 60 -In “Always on” mode main contactor o pens if all the following is true:60 +In “Always on” mode, the main contactor closes if all the following is true: 61 61 62 -* Other contactors are open; 63 -* There is an error from the the "Errors 1, 2 ..." bitfileds. 62 +* “Charging” contactor is open; 63 +* “Discharging” contactor is open; 64 +* there are no errors. 64 64 65 -In “A utomatic” mode, the main contactorclosesbyinternalalgorithmsatthesametimewithothercontactors.66 +In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true: 66 66 67 -* 68 +* “Charging current present” is set; 69 +* “Discharging current present” is set; 70 +* one or more errors persist. 68 68 69 69 To change the parameters of the main contactor, select the "Control → Main contactor" section: 70 70 ... ... @@ -109,13 +109,12 @@ 109 109 110 110 In this section: 111 111 112 -[[image:17399 70002016-142.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="600"]]115 +[[image:1739290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]] 113 113 114 114 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 115 115 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 116 116 * Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V; 117 117 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 118 -* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond; 119 119 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 120 120 * Relaxation between attempts – a duration between precharge attempts, millisecond; 121 121 * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; ... ... @@ -289,6 +289,7 @@ 289 289 * If "Discharge request" is received, procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section; 290 290 * If both signals received, "Charge request" has a priority. 291 291 294 + 292 292 In addition, the charge/discharge controller calculates and transmits to the upper-level system the maximum allowable current value with which the modular battery can be charged ("Charge current limit") and discharged ("Discharge current limit"), as well as the maximum regeneration current value with which the modular battery can be charged during operation under load ("Regeneration current limit"). The calculation of the charge, discharge and regeneration currents of the entire battery is performed based on the number of battery modules operating for charge or discharge and the maximum charge and discharge current values transmitted by them: 293 293 294 294 * "Charge current limit" and "Regeneration current limit" are calculated only if there is "Charge request";
- 1739976172181-924.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -29.0 KB - Content
- 1739976193603-451.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.8 KB - Content
- 1739976228035-922.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.2 KB - Content
- 1739976358691-364.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.8 KB - Content
- 1739976370994-390.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.2 KB - Content