Changes for page 3.3 Control

Last modified by Admin on 2025/05/30 16:50

From version 22.1
edited by Admin
on 2025/02/19 14:46
Change comment: There is no comment for this version
To version 23.1
edited by Admin
on 2025/02/19 14:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -57,18 +57,18 @@
57 57  * Always on;
58 58  * Automatic, when the main contactor closes by the internal charging and discharging algorithms at the same time with Precharging, Charging, Discharging and Charging/Discharging contactors.
59 59  
60 -In “Always on” mode, the main contactor closes if all the following is true:
60 +In “Always on” mode main contactor closes if all the following is true:
61 61  
62 -* “Charging” contactor is open;
63 -* “Discharging” contactor is open;
64 -* there are no errors.
62 +* Other contactors are open;
63 +* There are no errors from the "Errors 1, 2 ..." bitfileds.
65 65  
66 -In “Always on” mode, the main contactor opens if “Charging” and “Discharging” contactors are open and any of the following is true:
65 +In “Always on” mode main contactor opens if all the following is true:
67 67  
68 -* “Charging current present” is set;
69 -* “Discharging current present” is set;
70 -* one or more errors persist.
67 +* Other contactors are open;
68 +* There is an error from the the "Errors 1, 2 ..." bitfileds.
71 71  
70 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
71 +
72 72  To change the parameters of the main contactor, select the "Control → Main contactor" section:
73 73  
74 74  [[image:1734024131196-608.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="94" width="600"]]