Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -299,7 +299,7 @@ 299 299 300 300 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 301 301 302 -[[image:173929 2809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]]302 +[[image:1734089702994-738.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="600"]] 303 303 304 304 In this section: 305 305 ... ... @@ -319,13 +319,13 @@ 319 319 * Disconnect modules that are not ready to discharge – a flag for disconnecting modules that have the “Ready to discharge” signal cleared; 320 320 * Join modules on the “Charge request” signal – a flag to enable automatic modules joining if “Charge request” signal appears; 321 321 * Join modules on the “Discharge request” signal – a flag to enable automatic modules joining if “Discharge request” signal appears; 322 -* Maximum CONTINUOUS charge current limit – a maximum allowed continuous charging current of all the battery, A; 323 -* Maximum charge current limit – a maximum allowed charging current of all the battery, A; 324 324 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 325 325 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 324 +* Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 325 +* Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 326 326 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 327 -* Errors 1 (2) to open the charging/discharging contactor – errors that cause the maincharging/discharging contactor "Discharging" to open,328 -* Switch of the charging/discharging contactor on errors without a delay – a flag that allows the maincharging/discharging contactor to be opened without delay if errors are detected.327 +* Errors 1 (2) to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open, 328 +* Switch of the discharging contactor on errors without a delay – a flag that allows the main discharging contactor “Discharging” to be opened without delay if errors are detected. 329 329 330 330 === Module balancing === 331 331
- 1739292809635-913.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -60.7 KB - Content
- 1739970002016-142.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.2 KB - Content