Changes for page 3.3 Control
Last modified by Admin on 2025/05/30 16:50
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -112,12 +112,13 @@ 112 112 113 113 In this section: 114 114 115 -[[image:1739 290619354-792.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="117" width="600"]]115 +[[image:1739970002016-142.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="119" width="600"]] 116 116 117 117 * Precharge current threshold to close the discharging contactor – a current value to ensure that precharge process has finished and it is allowed to close the discharging contactor, A; 118 118 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 119 119 * Minimum voltage difference before and after contactors to finish precharging – a minimum voltage difference before and after contactors to ensure precharge process finished, V; 120 120 * Number of precharging attempts – maximum number of precharging attempts before setting the "Precharge error"; 121 +* Delay before current measurement – a delay before first current measurement after closing precharge, millisecond; 121 121 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 122 122 * Relaxation between attempts – a duration between precharge attempts, millisecond; 123 123 * Check the power dissipated in the preacharge resistor - a flag to enable the calculation of power dissipated in precharge resistor; ... ... @@ -291,7 +291,6 @@ 291 291 * If "Discharge request" is received, procedure is done as described in [[Discharge>>doc:||anchor="HDischarge"]] section; 292 292 * If both signals received, "Charge request" has a priority. 293 293 294 - 295 295 In addition, the charge/discharge controller calculates and transmits to the upper-level system the maximum allowable current value with which the modular battery can be charged ("Charge current limit") and discharged ("Discharge current limit"), as well as the maximum regeneration current value with which the modular battery can be charged during operation under load ("Regeneration current limit"). The calculation of the charge, discharge and regeneration currents of the entire battery is performed based on the number of battery modules operating for charge or discharge and the maximum charge and discharge current values transmitted by them: 296 296 297 297 * "Charge current limit" and "Regeneration current limit" are calculated only if there is "Charge request"; ... ... @@ -299,7 +299,7 @@ 299 299 300 300 The charge/discharge contactor control is configured in the “Control → Charge/Discharge” section: 301 301 302 -[[image:173 4089702994-738.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="92" width="600"]]302 +[[image:1739292809635-913.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="238" width="800"]] 303 303 304 304 In this section: 305 305 ... ... @@ -324,8 +324,8 @@ 324 324 * Maximum CONTINUOUS discharge current limit – a maximum allowed continuous discharging current of all the battery, A; 325 325 * Maximum discharge current limit – a maximum allowed discharging current of all the battery, A; 326 326 * Errors 1 (2) to disconnect all battery modules – errors that cause all battery modules to be disconnected from the common bus; 327 -* Errors 1 (2) to open the discharging contactor – errors that cause the main discharging contactor "Discharging" to open, 328 -* Switch of the discharging contactor on errors without a delay – a flag that allows the main discharging contactor “Discharging”to be opened without delay if errors are detected.327 +* Errors 1 (2) to open the charging/discharging contactor – errors that cause the main charging/discharging contactor "Discharging" to open, 328 +* Switch of the charging/discharging contactor on errors without a delay – a flag that allows the main charging/discharging contactor to be opened without delay if errors are detected. 329 329 330 330 === Module balancing === 331 331
- 1739970002016-142.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.2 KB - Content